Insulin pumps and continuous glucose monitors enable automatic control of blood glucose (BG) levels for patients with type 1 diabetes. Such controllers should carefully assess the likely future BG levels before injecting insulin, since the effects of insulin are prolonged, potentially deadly, and irreversible. Meals pose a strong challenge to this assessment as they create large, fast disturbances. Fortunately, meals have consistent and predictable effects, if their size and start time are known. We present a predictive algorithm that embeds meal detection and estimation into BG prediction. It uses a multiple hypothesis fault detector to identify meal occurrences, and linear Kalman filters to estimate meal sizes. It extrapolates and combines the state and state covariance estimates to form a prediction of BG values and uncertainties. These inputs enable controllers to assess and trade off the acute risks of low and chronic risks of high BG levels. We evaluate the predictor on simulated and clinical data.
Skip Nav Destination
ASME 2010 Dynamic Systems and Control Conference
September 12–15, 2010
Cambridge, Massachusetts, USA
Conference Sponsors:
- Dynamic Systems and Control Division
ISBN:
978-0-7918-4417-5
PROCEEDINGS PAPER
Predicting Blood Glucose Levels Around Meals for Patients With Type I Diabetes
Fraser Cameron,
Fraser Cameron
Stanford University, Stanford, CA
Search for other works by this author on:
Gu¨nter Niemeyer
Gu¨nter Niemeyer
Stanford University, Stanford, CA
Search for other works by this author on:
Fraser Cameron
Stanford University, Stanford, CA
Gu¨nter Niemeyer
Stanford University, Stanford, CA
Paper No:
DSCC2010-4060, pp. 289-296; 8 pages
Published Online:
January 25, 2011
Citation
Cameron, F, & Niemeyer, G. "Predicting Blood Glucose Levels Around Meals for Patients With Type I Diabetes." Proceedings of the ASME 2010 Dynamic Systems and Control Conference. ASME 2010 Dynamic Systems and Control Conference, Volume 1. Cambridge, Massachusetts, USA. September 12–15, 2010. pp. 289-296. ASME. https://doi.org/10.1115/DSCC2010-4060
Download citation file:
6
Views
0
Citations
Related Proceedings Papers
Related Articles
Microfabrication of a Device to Evaluate the Swelling of Glucose Sensitive Hydrogels Under Isochoric Conditions
J. Med. Devices (June,2009)
Backstepping Sliding Mode Gaussian Insulin Injection Control for Blood Glucose Regulation in Type I Diabetes Patient
J. Dyn. Sys., Meas., Control (September,2018)
Terminal Synergetic Control for Blood Glucose Regulation in Diabetes Patients
J. Dyn. Sys., Meas., Control (October,2018)
Related Chapters
Commercialising impedimetric biosensors: from laboratory to field
Impedimetric Biosensors for Medical Applications: Current Progress and Challenges
Summary and future direction
Nanomaterials in Glucose Sensing: Biomedical & Nanomedical Technologies - Concise Monographs
Real-Time Prediction Using Kernel Methods and Data Assimilation
Intelligent Engineering Systems through Artificial Neural Networks