Previously we had developed an articulated human body model to simulate the kinematic response to the external loadings, using CFDRC’s CoBi implicit multi-body solver. The anatomy-based human body model can accurately account for the surface loadings and surface interactions with the environment. A study is conducted to calibrate the joint properties (for instance, the joint rotational damping) of the articulated human body by comparing its response with those obtained from the PMHS test under moderate loading conditions. Additional adjustments in the input parameters also include the contact spring constants for joint stops at different joint locations. By comparing the computational results with the real scenarios, we fine tune these input parameters and further improve the accuracy of the articulated human body model. In order to simulate the effect of a C4 explosion on a human body in the open field, we employ a CFD model with a good resolution and the appropriate boundary treatment to obtain the blast loading condition on the human body surface more accurately. The numerical results of the blast simulation are shown to be comparable to the test data. With the interface to apply the blast pressure loading from the CFD simulation on the articulated human body surface, the articulated human body dynamics due to the C4 explosions are modeled and the simulation results are shown to be physiological reasonable.
Skip Nav Destination
ASME 2012 International Mechanical Engineering Congress and Exposition
November 9–15, 2012
Houston, Texas, USA
Conference Sponsors:
- ASME
ISBN:
978-0-7918-4518-9
PROCEEDINGS PAPER
An Enhanced Articulated Human Body Model Under C4 Blast Loadings
Andrzej J. Przekwas,
Andrzej J. Przekwas
CFD Research Corp., Huntsville, AL
Search for other works by this author on:
Kyle Ott,
Kyle Ott
Johns Hopkins University Applied Physics Laboratory, Columbia, MD
Search for other works by this author on:
Tim Harrigan,
Tim Harrigan
Johns Hopkins University Applied Physics Laboratory, Columbia, MD
Search for other works by this author on:
Jack Roberts,
Jack Roberts
Johns Hopkins University Applied Physics Laboratory, Columbia, MD
Search for other works by this author on:
Andrew Merkle
Andrew Merkle
Johns Hopkins University Applied Physics Laboratory, Columbia, MD
Search for other works by this author on:
X. G. Tan
CFD Research Corp., Huntsville, AL
R. Kannan
CFD Research Corp., Huntsville, AL
Andrzej J. Przekwas
CFD Research Corp., Huntsville, AL
Kyle Ott
Johns Hopkins University Applied Physics Laboratory, Columbia, MD
Tim Harrigan
Johns Hopkins University Applied Physics Laboratory, Columbia, MD
Jack Roberts
Johns Hopkins University Applied Physics Laboratory, Columbia, MD
Andrew Merkle
Johns Hopkins University Applied Physics Laboratory, Columbia, MD
Paper No:
IMECE2012-89067, pp. 821-828; 8 pages
Published Online:
October 8, 2013
Citation
Tan, XG, Kannan, R, Przekwas, AJ, Ott, K, Harrigan, T, Roberts, J, & Merkle, A. "An Enhanced Articulated Human Body Model Under C4 Blast Loadings." Proceedings of the ASME 2012 International Mechanical Engineering Congress and Exposition. Volume 2: Biomedical and Biotechnology. Houston, Texas, USA. November 9–15, 2012. pp. 821-828. ASME. https://doi.org/10.1115/IMECE2012-89067
Download citation file:
10
Views
0
Citations
Related Proceedings Papers
Related Articles
Simulation and Animation of Musculoskeletal Joint System
J Biomech Eng (November,1993)
Anatomical Study of the Radius and Center of Curvature of the Distal Femoral Condyle
J Biomech Eng (September,2010)
Related Chapters
Feedback-Aided Minimum Joint Motion
Robot Manipulator Redundancy Resolution
Pseudoinverse Method and Singularities Discussed
Robot Manipulator Redundancy Resolution
Manipulability-Maximizing SMP Scheme
Robot Manipulator Redundancy Resolution