Abstract

The coiling temperature control problem for soft cooling pattern was investigated in this study. It has been found that the abnormal coiling temperature control behavior was caused by the use of incorrect preset value of spray efficiency modifier and non-linearity in the spray efficiency when the cooling pattern was overridden. To solve this problem, a cooling pattern model is hence established. By calculating the ratio of cooling rate for soft cooling pattern, both the spray efficiency modifier as well as the equivalent spray quantity compensation multiplier for cooling pattern override has been derived. The coiling temperature control and model adaptation program was then revised by adding the compensation multiplier in case of cooling pattern override. After the revision of spray efficiency modifier and coiling temperature control program, it was noted that the coiling temperature control of soft cooling pattern was significantly improved.

This content is only available via PDF.