Endoscopes are used in medicine to inspect inside the body without having to perform open surgery on the patient. The current gold standard for screening and diagnosing colorectal cancer and inflammatory bowel disease is the colonoscopy. This procedure uses a flexible endoscope to inspect the wall of the large intestine, from the rectum to the caecum, for cancerous or precancerous lesions. This screening is very important since early detection of colon cancer is 85–95% successfully treated. Unfortunately, there is only a 30% compliance rate for colonoscopies in the United States. This lack of compliance is due largely in part to the uncomfortable nature of the procedure, caused by the fact that the stiff scope is difficult to manipulate in the non-rigid colon, leading to “looping” of the scope (see Fig. 1), and that the clinician is essentially navigating in near blind conditions during the procedure.
Skip Nav Destination
ASME 2008 Summer Bioengineering Conference
June 25–29, 2008
Marco Island, Florida, USA
Conference Sponsors:
- Bioengineering Division
ISBN:
978-0-7918-4321-5
PROCEEDINGS PAPER
Endoscope Shape-Tracker Based on Embedded Fluorescent Dyes in an Optical Fiber
Robb M. Gavalis,
Robb M. Gavalis
Tufts University, Medford, MA
Search for other works by this author on:
Peter Y. Wong,
Peter Y. Wong
Tufts University, Medford, MA
Search for other works by this author on:
Lothar Lilge,
Lothar Lilge
University of Toronto, Toronto, ON, Canada
Search for other works by this author on:
Caroline G. L. Cao
Caroline G. L. Cao
Tufts University, Medford, MA
Search for other works by this author on:
Robb M. Gavalis
Tufts University, Medford, MA
Hua Xing
Tufts University, Medford, MA
Peter Y. Wong
Tufts University, Medford, MA
Lothar Lilge
University of Toronto, Toronto, ON, Canada
Caroline G. L. Cao
Tufts University, Medford, MA
Paper No:
SBC2008-192809, pp. 461-462; 2 pages
Published Online:
March 13, 2014
Citation
Gavalis, RM, Xing, H, Wong, PY, Lilge, L, & Cao, CGL. "Endoscope Shape-Tracker Based on Embedded Fluorescent Dyes in an Optical Fiber." Proceedings of the ASME 2008 Summer Bioengineering Conference. ASME 2008 Summer Bioengineering Conference, Parts A and B. Marco Island, Florida, USA. June 25–29, 2008. pp. 461-462. ASME. https://doi.org/10.1115/SBC2008-192809
Download citation file:
4
Views
Related Proceedings Papers
Related Articles
Design of a Bending Section Auto-Driven Mechanism for Colonoscope
J. Med. Devices (June,2009)
Localization of the Distal Tip in the Colonoscopy Training Model Using Light Sensors
J. Med. Devices (June,2011)
Design of an Endoscope Shape Tracker to Guide Navigation in Colonoscopy
J. Med. Devices (June,2008)
Related Chapters
Conclusion & executive summary
Photodynamic Therapy Mediated by Fullerenes and their Derivatives
Introduction and scope
Impedimetric Biosensors for Medical Applications: Current Progress and Challenges
Experimental Studies
Nanoparticles and Brain Tumor Treatment