The objective of this study was to measure and compare the fatigue behavior of 316L stainless steel, titanium (Ti-6Al-4V), and cobalt chromium molybdenum (CoCrMo) spinal rods in vitro. Spinal rods are used to immobilize the spine while fusion of the vertebrae occurs (spinal arthrodesis). Implanted spinal rods are subjected to cyclic loading and are therefore susceptible to fatigue failure if fusion does not occur sufficiently quickly. A significant number of spinal rod fatigue failures have been observed between six months to one year following surgical implantation. On average, the spine will experience about 3 million cycles per year. Stress overloads can result in permanent deformation or immediate failure of the rod, however these overloads are seldom the root cause of failure—rods typically fail by fatigue [1].
Skip Nav Destination
ASME 2010 Summer Bioengineering Conference
June 16–19, 2010
Naples, Florida, USA
Conference Sponsors:
- Bioengineering Division
ISBN:
978-0-7918-4403-8
PROCEEDINGS PAPER
Fatigue Behavior of Stainless Steel, Titanium, and Cobalt Chromium Molybdenum Spinal Rods
Anthony Paris,
Anthony Paris
University of Alaska Anchorage, Anchorage, AK
Search for other works by this author on:
Alex Bergeron,
Alex Bergeron
University of Alaska Anchorage, Anchorage, AK
Search for other works by this author on:
Matthew Cullin,
Matthew Cullin
University of Alaska Anchorage, Anchorage, AK
Search for other works by this author on:
Andres Munk
Andres Munk
Macomb Orthopedic Surgeons, Warren, MI
Search for other works by this author on:
Anthony Paris
University of Alaska Anchorage, Anchorage, AK
Alex Bergeron
University of Alaska Anchorage, Anchorage, AK
Matthew Cullin
University of Alaska Anchorage, Anchorage, AK
Andres Munk
Macomb Orthopedic Surgeons, Warren, MI
Paper No:
SBC2010-19720, pp. 849-850; 2 pages
Published Online:
July 15, 2013
Citation
Paris, A, Bergeron, A, Cullin, M, & Munk, A. "Fatigue Behavior of Stainless Steel, Titanium, and Cobalt Chromium Molybdenum Spinal Rods." Proceedings of the ASME 2010 Summer Bioengineering Conference. ASME 2010 Summer Bioengineering Conference, Parts A and B. Naples, Florida, USA. June 16–19, 2010. pp. 849-850. ASME. https://doi.org/10.1115/SBC2010-19720
Download citation file:
26
Views
0
Citations
Related Proceedings Papers
Related Articles
A Multi-Station Rolling/Sliding Tribotester for Knee Bearing Materials
J. Tribol (April,2004)
An Experimental Study of Ratchetting During Indentation of 316L Stainless Steel
J. Eng. Mater. Technol (July,1998)
Design of an Endoreactor for the Cultivation of a Joint-Like-Structure
J. Med. Devices (June,2009)
Related Chapters
Understanding the Problem
Design and Application of the Worm Gear
Fatigue Analysis in the Connecting Rod of MF285 Tractor by Finite Element Method
International Conference on Advanced Computer Theory and Engineering, 4th (ICACTE 2011)
Introduction and Definitions
Handbook on Stiffness & Damping in Mechanical Design