A common clinical practice in interventional procedures, is the deployment of two or more overlapping stents, especially in areas of branches and bifurcations where the stenotic area is diffuse and cannot be covered by a single stent or in the cases of treating long or recurrent lesions. However, complex in vivo conditions such as vessel tortuousity, high curvature, vascular wall stresses as well as blood flow wall shear stresses and diffuse calcification, may cause additional interactions within overlapping stents resulting in enhanced surface damage and fracture of stents. Preliminary studies have revealed that some stents undergo corrosion and fatigue-induced fracture in vivo, with significant release of metallic ions into surrounding tissues. A direct link between corrosion and in-stent restenosis has not been clearly established; nonetheless in vitro studies have shown that relatively high concentrations of heavy metal ions can stimulate both inflammatory and fibrotic reactions, which are the main steps in the process of restenosis. This study presents the outcome of in vitro accelerated biomechanical testing of Nitinol stents placed in mock arteries in single and overlapping configurations with various degrees of curvature. The effect of overlapping dissimilar materials was also investigated by testing multiple alloy stent combinations combining NiTi with CoCr or SS stents.
Skip Nav Destination
ASME 2012 Summer Bioengineering Conference
June 20–23, 2012
Fajardo, Puerto Rico, USA
Conference Sponsors:
- Bioengineering Division
ISBN:
978-0-7918-4480-9
PROCEEDINGS PAPER
Stent Overlapping and Geometric Curvature Influence the Structural Integrity and Surface Characteristics of Coronary Stents
Konstantinos Kapnisis,
Konstantinos Kapnisis
Cyprus University of Technology, Lemesos, Cyprus
Search for other works by this author on:
Dina Halwani,
Dina Halwani
University of Alabama at Birmingham, Birmingham, AL
Search for other works by this author on:
Brigitta Brott,
Brigitta Brott
University of Alabama at Birmingham, Birmingham, AL
Search for other works by this author on:
Jack Lemons,
Jack Lemons
University of Alabama at Birmingham, Birmingham, AL
Search for other works by this author on:
Peter Anderson,
Peter Anderson
University of Alabama at Birmingham, Birmingham, AL
Search for other works by this author on:
Andreas Anayiotos
Andreas Anayiotos
Cyprus University of Technology, Lemesos, Cyprus
Search for other works by this author on:
Konstantinos Kapnisis
Cyprus University of Technology, Lemesos, Cyprus
Dina Halwani
University of Alabama at Birmingham, Birmingham, AL
Brigitta Brott
University of Alabama at Birmingham, Birmingham, AL
Jack Lemons
University of Alabama at Birmingham, Birmingham, AL
Peter Anderson
University of Alabama at Birmingham, Birmingham, AL
Andreas Anayiotos
Cyprus University of Technology, Lemesos, Cyprus
Paper No:
SBC2012-80231, pp. 559-560; 2 pages
Published Online:
July 19, 2013
Citation
Kapnisis, K, Halwani, D, Brott, B, Lemons, J, Anderson, P, & Anayiotos, A. "Stent Overlapping and Geometric Curvature Influence the Structural Integrity and Surface Characteristics of Coronary Stents." Proceedings of the ASME 2012 Summer Bioengineering Conference. ASME 2012 Summer Bioengineering Conference, Parts A and B. Fajardo, Puerto Rico, USA. June 20–23, 2012. pp. 559-560. ASME. https://doi.org/10.1115/SBC2012-80231
Download citation file:
2
Views
Related Proceedings Papers
Related Articles
Sequential Structural and Fluid Dynamic Numerical Simulations of a Stented Bifurcated Coronary Artery
J Biomech Eng (December,2011)
Structural Life Expectancy of Marine Vessels: Ultimate Strength, Corrosion, Fatigue, Fracture, and Systems
ASME J. Risk Uncertainty Part B (March,2015)
A Thin Film Nitinol Heart Valve
J Biomech Eng (November,2005)
Related Chapters
Section III: Subsections NC and ND — Class 2 and 3 Components
Companion Guide to the ASME Boiler and Pressure Vessel Code, Volume 1, Fourth Edition
Introductory Information
The Stress Analysis of Cracks Handbook, Third Edition
Understanding the Problem
Design and Application of the Worm Gear