Transport of bioactive agents through the blood is essential for cardiovascular regulatory processes and drug delivery. Bioactive agents and other solutes infused into the blood through the wall of a blood vessel or released into the blood from an area in the vessel wall spread downstream of the infusion/release region and form a thin boundary layer in which solute concentration is higher than in the rest of the blood. Bioactive agents distributed along the vessel wall affect endothelial cells and regulate biological processes, such as thrombus formation, atherogenesis, and vascular remodeling. To calculate the concentration of solutes in the boundary layer, researchers have generally used numerical simulations. However, to investigate the effect of blood flow, infusion rate, and vessel geometry on the concentration of different solutes, many simulations are needed, leading to a time-consuming effort. In this paper, a relatively simple formula to quantify concentrations in a tube downstream of an infusion/release region is presented. Given known blood-flow rates, tube radius, solute diffusivity, and the length of the infusion region, this formula can be used to quickly estimate solute concentrations when infusion rates are known or to estimate infusion rates when solute concentrations at a point downstream of the infusion region are known. The developed formula is based on boundary layer theory and physical principles. The formula is an approximate solution of the advection-diffusion equations in the boundary layer region when solute concentration is small (dilute solution), infusion rate is modeled as a mass flux, and there is no transport of solute through the wall or chemical reactions downstream of the infusion region. Wall concentrations calculated using the formula developed in this paper were compared to the results from finite element models. Agreement between the results was within 10%. The developed formula could be used in experimental procedures to evaluate drug efficacy, in the design of drug-eluting stents, and to calculate rates of release of bioactive substances at active surfaces using downstream concentration measurements. In addition to being simple and fast to use, the formula gives accurate quantifications of concentrations and infusion rates under steady-state and oscillatory flow conditions, and therefore can be used to estimate boundary layer concentrations under physiological conditions.

1.
Davies
,
P. F.
, 1995, “
Flow-Mediated Endothelial Mechanotransduction
,”
Physiol. Rev.
0031-9333,
75
(
3
), pp.
519
560
.
2.
Kamm
,
R. D.
, 2002, “
Cellular Fluid Mechanics
,”
Annu. Rev. Fluid Mech.
0066-4189,
34
, pp.
211
232
.
3.
Turitto
,
V. T.
, 1981, “
Blood Viscosity, Mass Transport and Thrombogenesis
,”
Progress in Hemostasis and Thrombosis
,
T. M.
Spaet
, ed.,
Grune & Stratton
,
New York
, Vol.
6
, pp.
139
174
.
4.
Basmadjian
,
D.
, 1990, “
The Effect of Flow and Mass Transfer in Thrombogenesis
,”
Ann. Biomed. Eng.
0090-6964,
18
, pp.
685
709
.
5.
Tarbell
,
J. M.
, 2003, “
Mass Transport in Arteries and the Localization of Atherosclerosis
,”
Annu. Rev. Biomed. Eng.
1523-9829,
5
, pp.
79
118
.
6.
Sakariassen
,
K. S.
,
Hanson
,
S. R.
, and
Cadroy
,
Y.
, 2001, “
Methods and Models to Evaluate Shear-Dependent and Surface Reactivity-Dependent Antithrombotic Efficacy
,”
Thromb. Res.
0049-3848,
104
, pp.
149
174
.
7.
Lincoff
,
A. M.
,
Topol
,
E. J.
, and
Ellis
,
S. G.
, 1994, “
Local Drug Delivery for the Prevention of Restenosis: Fact, Fancy and Future
,”
Circulation
0009-7322,
90
(
4
), pp.
2070
2084
.
8.
Markou
,
C. P.
,
Lutostansky
,
E. M.
,
Ku
,
D. N.
, and
Hanson
,
S. R.
, 1998, “
A Novel Method for Efficient Drug Delivery
,”
Ann. Biomed. Eng.
0090-6964,
26
, pp.
502
511
.
9.
Chen
,
C.
,
Lumsden
,
A. B.
, and
Hanson
,
S. R.
, 2000, “
Local Infusion of Heparin Reduces Anastomic Neointimal Hyperplasia in Aortoiliac Expanded Polytetrafluoroethylene Bypass Grafts in Baboons
,”
J. Vasc. Surg.
0741-5214,
31
, pp.
354
363
.
10.
Balakrishnan
,
B.
,
Tzafriri
,
A. R.
,
Seifert
,
P.
,
Groothuis
,
A.
,
Rogers
,
C.
, and
Edelman
,
E. R.
, 2005, “
Strut Position, Blood Flow, and Drug Deposition: Implications for Single and Overlapping Drug-Eluting Stents
,”
Circulation
0009-7322,
111
, pp.
2958
2965
.
11.
Cussler
,
E. L.
, 1984,
Diffusion, Mass Transfer in Fluid Systems
,
Cambridge University Press
,
New York
, Chap. 11.
12.
Bird
,
R. B.
,
Stewart
,
W. E.
, and
Lightfoot
,
E. N.
, 1960,
Transport Phenomena
,
Wiley
,
New York
, Chap. 11.
13.
Fung
,
Y. C.
, 1993,
Biomechanics Mechanical Properties of Living Tissues
,
Springer-Verlag
,
New York
, Chap. 3.
14.
Basmadjian
,
D.
, and
Sefton
,
M. V.
, 1983, “
Relationship between Release Rate and Surface Concentration for Heparinized Materials
,”
J. Biomed. Mater. Res.
0021-9304,
17
, pp.
509
518
.
15.
Fay
,
J. A.
, 1994,
Introduction to Fluid Mechanics
,
MIT
,
Cambridge, MA
, Chap. 10.
16.
Soliman
,
M.
, and
Chambré
,
P. L.
, 1967, “
On the Time Dependent Lévêque Problem
,”
Int. J. Heat Mass Transfer
0017-9310,
10
, pp.
169
180
.
17.
Hanson
,
S. R.
, and
Sakariassen
,
K. S.
, 1998, “
Blood Flow and Antithrombotic Drug Effects
,”
Am. Heart J.
0002-8703,
135
, pp.
S132
S145
.
You do not currently have access to this content.