Computational models of arterial growth and remodeling promise to increase our understanding of basic biological processes, such as development, tissue maintenance, and aging, the biomechanics of functional adaptation, the progression and treatment of disease, responses to injuries, and even the design of improved replacement vessels and implanted medical devices. Ensuring reliability of and confidence in such models requires appropriate attention to verification and validation, including parameter sensitivity studies. In this paper, we classify different types of parameters within a constrained mixture model of arterial growth and remodeling; we then evaluate the sensitivity of model predictions to parameter values that are not known directly from experiments for cases of modest sustained alterations in blood flow and pressure as well as increased axial extension. Particular attention is directed toward complementary roles of smooth muscle vasoactivity and matrix turnover, with an emphasis on mechanosensitive changes in the rates of turnover of intramural fibrillar collagen and smooth muscle in maturity. It is shown that vasoactive changes influence the rapid change in caliber that is needed to maintain wall shear stress near its homeostatic level and the longer term changes in wall thickness that are needed to maintain circumferential wall stress near its homeostatic target. Moreover, it is shown that competing effects of intramural and wall shear stress-regulated rates of turnover can develop complex coupled responses. Finally, results demonstrate that the sensitivity to parameter values depends upon the type of perturbation from normalcy, with changes in axial stretch being most sensitive consistent with empirical reports.
Skip Nav Destination
e-mail: jhumphrey@tamu.edu
Article navigation
October 2009
Research Papers
Parameter Sensitivity Study of a Constrained Mixture Model of Arterial Growth and Remodeling
A. Valentín,
A. Valentín
Department of Biomedical Engineering,
Texas A&M University
, 337 Zachry Engineering Center, 3120 TAMU, College Station, TX 77843-3120
Search for other works by this author on:
J. D. Humphrey
J. D. Humphrey
Department of Biomedical Engineering,
e-mail: jhumphrey@tamu.edu
Texas A&M University
, 337 Zachry Engineering Center, 3120 TAMU, College Station, TX 77843-3120
Search for other works by this author on:
A. Valentín
Department of Biomedical Engineering,
Texas A&M University
, 337 Zachry Engineering Center, 3120 TAMU, College Station, TX 77843-3120
J. D. Humphrey
Department of Biomedical Engineering,
Texas A&M University
, 337 Zachry Engineering Center, 3120 TAMU, College Station, TX 77843-3120e-mail: jhumphrey@tamu.edu
J Biomech Eng. Oct 2009, 131(10): 101006 (11 pages)
Published Online: September 2, 2009
Article history
Received:
December 8, 2008
Revised:
May 25, 2009
Published:
September 2, 2009
Citation
Valentín, A., and Humphrey, J. D. (September 2, 2009). "Parameter Sensitivity Study of a Constrained Mixture Model of Arterial Growth and Remodeling." ASME. J Biomech Eng. October 2009; 131(10): 101006. https://doi.org/10.1115/1.3192144
Download citation file:
Get Email Alerts
A Numerical Study of Crack Penetration and Deflection at the Interface Between Peritubular and Intertubular Dentin
J Biomech Eng (December 2024)
Related Articles
Manipulation of Remodeling Pathways to Enhance the Mechanical Properties of a Tissue Engineered Blood Vessel
J Biomech Eng (December,2002)
Differential Passive and Active Biaxial Mechanical Behaviors of Muscular and Elastic Arteries: Basilar Versus Common Carotid
J Biomech Eng (May,2011)
Development of A Medical Device for Quantitative Physical Therapies
J. Med. Devices (June,2008)
Related Proceedings Papers
Related Chapters
Clinical issues and experience
Mechanical Blood Trauma in Circulatory-Assist Devices
Vibration Analysis of the Seated Human Body in Vertical Direction
International Conference on Computer Technology and Development, 3rd (ICCTD 2011)
Concluding remarks
Mechanical Blood Trauma in Circulatory-Assist Devices