In the early embryo, the primitive heart tube (HT) undergoes the morphogenetic process of c-looping as it bends and twists into a c-shaped tube. Despite intensive study for nearly a century, the physical forces that drive looping remain poorly understood. This is especially true for the bending component, which is the focus of this paper. For decades, experimental measurements of mitotic rates had seemingly eliminated differential growth as the cause of HT bending, as it has commonly been thought that the heart grows almost exclusively via hyperplasia before birth and hypertrophy after birth. Recently published data, however, suggests that hypertrophic growth may play a role in looping. To test this idea, we developed finite-element models that include regionally measured changes in myocardial volume over the HT. First, models based on idealized cylindrical geometry were used to simulate the bending process in isolated hearts, which bend without the complicating effects of external loads. With the number of free parameters in the model reduced to the extent possible, stress and strain distributions were compared to those measured in embryonic chick hearts that were isolated and cultured for 24 h. The results show that differential growth alone yields results that agree reasonably well with the trends in our data, but adding active changes in myocardial cell shape provides closer quantitative agreement with stress measurements. Next, the estimated parameters were extrapolated to a model based on realistic 3D geometry reconstructed from images of an actual chick heart. This model yields similar results and captures quite well the basic morphology of the looped heart. Overall, our study suggests that differential hypertrophic growth in the myocardium (MY) is the primary cause of the bending component of c-looping, with other mechanisms possibly playing lesser roles.
Skip Nav Destination
e-mail: jiang.yao@3ds.com
Article navigation
August 2014
Research-Article
Bending of the Looping Heart: Differential Growth Revisited
Yunfei Shi,
Yunfei Shi
Department of Biomedical Engineering,
e-mail: yunfei.shi@wustl.edu
Washington University
,Saint Louis, MO 63130
e-mail: yunfei.shi@wustl.edu
Search for other works by this author on:
Jiang Yao,
e-mail: jiang.yao@3ds.com
Jiang Yao
Dassault Systemes Simulia Corp.
,166 Valley Street
,Providence, RI 02902-2499
e-mail: jiang.yao@3ds.com
Search for other works by this author on:
Gang Xu,
Gang Xu
Department of Engineering and Physics,
e-mail: gxu@uco.edu
University of Central Oklahoma
,Edmond, OK 73034
e-mail: gxu@uco.edu
Search for other works by this author on:
Larry A. Taber
Larry A. Taber
1
Department of Biomedical Engineering,
e-mail: lat@wustl.edu
Washington University
,Saint Louis, MO 63130
e-mail: lat@wustl.edu
1Corresponding author.
Search for other works by this author on:
Yunfei Shi
Department of Biomedical Engineering,
e-mail: yunfei.shi@wustl.edu
Washington University
,Saint Louis, MO 63130
e-mail: yunfei.shi@wustl.edu
Jiang Yao
Dassault Systemes Simulia Corp.
,166 Valley Street
,Providence, RI 02902-2499
e-mail: jiang.yao@3ds.com
Gang Xu
Department of Engineering and Physics,
e-mail: gxu@uco.edu
University of Central Oklahoma
,Edmond, OK 73034
e-mail: gxu@uco.edu
Larry A. Taber
Department of Biomedical Engineering,
e-mail: lat@wustl.edu
Washington University
,Saint Louis, MO 63130
e-mail: lat@wustl.edu
1Corresponding author.
*All supplemental material for this paper can be accessed in the “SUPPLEMENTAL DATA” tab in the online version of this paper on the ASME digital collection.
Contributed by the Bioengineering Division of ASME for publication in the Journal of Biomechanical Engineering. Manuscript received October 15, 2013; final manuscript received January 20, 2014; accepted manuscript posted February 6, 2014; published online June 2, 2014. Assoc. Editor: Hai-Chao Han.
J Biomech Eng. Aug 2014, 136(8): 081002 (15 pages)
Published Online: June 2, 2014
Article history
Received:
October 15, 2013
Revision Received:
January 20, 2014
Accepted:
February 6, 2014
Citation
Shi, Y., Yao, J., Xu, G., and Taber, L. A. (June 2, 2014). "Bending of the Looping Heart: Differential Growth Revisited." ASME. J Biomech Eng. August 2014; 136(8): 081002. https://doi.org/10.1115/1.4026645
Download citation file:
Get Email Alerts
Cited By
Related Articles
Biomechanical Measurements of Torsion-Tension Coupling in Human Cadaveric Femurs
J Biomech Eng (January,2011)
Computational Model of the Cerebral Ventricles in Hydrocephalus
J Biomech Eng (May,2010)
3-D Finite-Element Models of Human and Monkey Fingertips to Investigate the Mechanics of Tactile Sense
J Biomech Eng (October,2003)
On the Biaxial Mechanical Response of Porcine Tricuspid Valve Leaflets
J Biomech Eng (October,2016)
Related Proceedings Papers
Related Chapters
Introduction and Definitions
Handbook on Stiffness & Damping in Mechanical Design
Vibration Analysis of the Seated Human Body in Vertical Direction
International Conference on Computer Technology and Development, 3rd (ICCTD 2011)
Computer Aided Geometric Modelling
Computer Aided Design and Manufacturing