A new method of in-situ heat flux gage calibration is evaluated for use in convective facilities with high heat transfer and fast time response. A Heat Flux Microsensor (HFM) was used in a shock tunnel to simultaneously measure time-resolved surface heat flux and temperature from two sensors fabricated on the same substrate. A method is demonstrated for estimating gage sensitivity and frequency response from the data generated during normal transient test runs. To verify heat flux sensitivity, shock tunnel data are processed according to a one-dimensional semi-infinite conduction model based on measured thermal properties for the gage substrate. Heat flux signals are converted to temperature, and vice versa. Comparing measured and calculated temperatures allows an independent calibration of sensitivity for each data set. The results match gage calibrations performed in convection at the stagnation point of a free jet and done by the manufacturer using radiation. In addition, a finite-difference model of the transient behavior of the heat flux sensor is presented to demonstrate the first-order response to a step input in heat flux. Results are compared with shock passing data from the shock tunnel. The Heat Flux Microsensor recorded the heat flux response with an estimated time constant of 6 μs, which demonstrates a frequency response covering DC to above 100 kHz.
Skip Nav Destination
Article navigation
December 1995
Research Papers
High-Frequency Heat Flux Sensor Calibration and Modeling
D. G. Holmberg,
D. G. Holmberg
Mechanical Engineering Department, Virginia Polytechnic Institute and State University, Blacksburg, VA 24061-0238
Search for other works by this author on:
T. E. Diller
T. E. Diller
Mechanical Engineering Department, Virginia Polytechnic Institute and State University, Blacksburg, VA 24061-0238
Search for other works by this author on:
D. G. Holmberg
Mechanical Engineering Department, Virginia Polytechnic Institute and State University, Blacksburg, VA 24061-0238
T. E. Diller
Mechanical Engineering Department, Virginia Polytechnic Institute and State University, Blacksburg, VA 24061-0238
J. Fluids Eng. Dec 1995, 117(4): 659-664 (6 pages)
Published Online: December 1, 1995
Article history
Received:
April 20, 1994
Revised:
February 16, 1995
Online:
December 4, 2007
Citation
Holmberg, D. G., and Diller, T. E. (December 1, 1995). "High-Frequency Heat Flux Sensor Calibration and Modeling." ASME. J. Fluids Eng. December 1995; 117(4): 659–664. https://doi.org/10.1115/1.2817319
Download citation file:
Get Email Alerts
Related Articles
Experimental Performance of a Heat Flux Microsensor
J. Eng. Gas Turbines Power (April,1991)
A New Transient High Heat Flux Convection Calibration Facility for Heat Transfer Gauges in High Enthalpy Flows
J. Heat Transfer (April,2018)
Frequency Response Characteristics of an Active Heat Flux Gage
J. Heat Transfer (August,1998)
Design and Calibration of a Local Heat-Flux Measurement System for Unsteady Flows
J. Heat Transfer (May,1989)
Related Proceedings Papers
Related Chapters
Transient Temperature and Heat Flux Measurement Using Thin-Film Microsensors
Ultrasonic Welding of Lithium-Ion Batteries
Radiation
Thermal Management of Microelectronic Equipment
Radiation
Thermal Management of Microelectronic Equipment, Second Edition