Hydrodynamic experiments measuring longitudinal pressure-drop versus flow rate are conducted for turbulent flow of air (channel hydraulic diameter based Reynolds number range of 2300 to 6860) through near-compact heat exchanger models with rod bundles having aligned (inline) arrangement. Effects of the flow (Re), the geometry parameters, and number of rods of the test models on the nondimensional pressure-drop ξ are studied in detail. Treating the near compact heat exchanger model as a porous medium, a dimensional pressure-drop versus average velocity of flow (U) model similar in content to a non-Darcy porous medium model, is shown to fit the experimental data with fair accuracy. Variation in form drag related to, and induced by the flow and geometric parameters are shown to be the reason for the pressure-drop variations of different models. The relation between the porous medium type model versus U) and the “ξ versus Re” model is discussed with careful attention to the differences in the two transitions viz. laminar to turbulent and viscous-drag to form-drag dominated flow inside the models. A proposed correlation for predicting ξ, ably capturing all of the form effects induced by the flow and geometric parameters, is found to give predictions with ±20% accuracy.
Skip Nav Destination
Article navigation
November 2004
Article
Turbulent Flow Hydrodynamic Experiments in Near-Compact Heat Exchanger Models With Aligned Tubes
L. Wilson,
L. Wilson
Heat Transfer and Thermal Power Laboratory, Department of Mechanical Engineering, Indian Institute of Technology Madras, Chennai, Tamil Nadu 600036, India
Search for other works by this author on:
Arunn Narasimhan,
Arunn Narasimhan
Heat Transfer and Thermal Power Laboratory, Department of Mechanical Engineering, Indian Institute of Technology Madras, Chennai, Tamil Nadu 600036, India
Search for other works by this author on:
S. P. Venkateshan
S. P. Venkateshan
Heat Transfer and Thermal Power Laboratory, Department of Mechanical Engineering, Indian Institute of Technology Madras, Chennai, Tamil Nadu 600036, India
Search for other works by this author on:
L. Wilson
Heat Transfer and Thermal Power Laboratory, Department of Mechanical Engineering, Indian Institute of Technology Madras, Chennai, Tamil Nadu 600036, India
Arunn Narasimhan
Heat Transfer and Thermal Power Laboratory, Department of Mechanical Engineering, Indian Institute of Technology Madras, Chennai, Tamil Nadu 600036, India
S. P. Venkateshan
Heat Transfer and Thermal Power Laboratory, Department of Mechanical Engineering, Indian Institute of Technology Madras, Chennai, Tamil Nadu 600036, India
Contributed by the Fluids Engineering Division for publication in the JOURNAL OF FLUIDS ENGINEERING. Manuscript received by the Fluids Engineering Division November 28, 2003; revised manuscript received June 4, 2004. Review conducted by: M. Volkan O¨tu¨gen.
J. Fluids Eng. Nov 2004, 126(6): 990-996 (7 pages)
Published Online: March 11, 2005
Article history
Received:
November 28, 2003
Revised:
June 4, 2004
Online:
March 11, 2005
Citation
Wilson , L., Narasimhan, A., and Venkateshan, S. P. (March 11, 2005). "Turbulent Flow Hydrodynamic Experiments in Near-Compact Heat Exchanger Models With Aligned Tubes ." ASME. J. Fluids Eng. November 2004; 126(6): 990–996. https://doi.org/10.1115/1.1845553
Download citation file:
Get Email Alerts
Related Articles
Pressure Drop Through Anisotropic Porous Mediumlike Cylinder Bundles in Turbulent Flow Regime
J. Fluids Eng (October,2008)
Modified Hazen-Dupuit-Darcy Model for Forced Convection of a Fluid With Temperature-Dependent Viscosity
J. Heat Transfer (February,2001)
Recent Mathematical Models for Turbulent Flow in Saturated Rigid Porous Media
J. Fluids Eng (December,2001)
Alternative Models of Turbulence in a Porous Medium, and Related Matters
J. Fluids Eng (December,2001)
Related Proceedings Papers
Related Chapters
Fluidelastic Instability of Tube Bundles in Single-Phase Flow
Flow-Induced Vibration Handbook for Nuclear and Process Equipment
Random Turbulence Excitation in Single-Phase Flow
Flow-Induced Vibration Handbook for Nuclear and Process Equipment
Heat Transfer and Pressure Drop Correlations for Compact Heat Exchangers with Multi-Region Louver Fins
Inaugural US-EU-China Thermophysics Conference-Renewable Energy 2009 (UECTC 2009 Proceedings)