This paper is focused on the design of a portable and semi-automatic product that allows human blood typing in a short time interval. To solve the technical and mechanical issues, innovative technologies in the areas of industrial design, electronics, and mechanical engineering were incorporated. Thus, we have developed a mechanical system that performs a fast and secure mixing of samples based on the manual plate test. This product concept aims to determinate human blood type in less than 5 min using image-processing algorithms into the mechatronic system. It incorporates formal harmonic aspects as well as some important features, such as ergonomics, portability, safety, security, simple maintenance, and easy to use.
Issue Section:
Technical Brief
References
1.
Ferraz
, A.
, Carvalho
, V.
, Soares
, F.
, and Leão
, C. P.
, 2011
, “Characterization of Blood Samples Using Image Processing Techniques
,” Sens. Actuators A
, 172
(1
), pp. 308
–314
.2.
Ferraz
, A.
, Carvalho
, V.
, and Brandão
, P.
, 2010
, “Automatic Determination of Human Blood Types Using Image Processing Techniques
,” Third International Conference on Biomedical Electronics and Devices (BIODEVICES 2010
), Valencia, Spain, Jan. 20–23, Jan. 26–29, pp. 69
–74
.3.
Ferraz
, A.
, Carvalho
, V.
, and Soares
, F.
, 2010
, “Development of a Human Blood Type Detection Automatic System
,” EUROSENSORS XXIV
, Linz, Austria, Sept. 5–8, pp. 496
–499
.4.
Ferraz
, A.
, Moreira
, V.
, Silva
, D.
, Carvalho
, V.
, and Soares
, F.
, 2011
, “Automatic System for Blood Type Classification Using Image Processing Techniques
,” International Conference on Biomedical Electronics and Devices
(BIODEVICES 2011
), Rome, Italy, Jan. 26–29, pp. 26
–29
.5.
EU
, 2010
, “Manual of Optimal Blood Use
,” European Union
, Brussels, Belgium
.6.
Fisher
, R. A.
, 1947
, “The Rhesus Factor: A Study in Scientific Method
,” Am. Sci.
, 35
, pp. 95
–103
.7.
EU
, 2010
, “Medical Devices: Guidance Document—Classification of Medical Devices
,” European Commission
, Brussels, Belgium, Paper No. MEDDEV 2.4/1 Rev. 9.8.
Woodson
, W. E.
, 1981
, Human Factors Design Handbook
, McGraw-Hill
, New York
.9.
Moreira
, V.
, Machado
, J.
, Carvalho
, V.
, Soares
, F.
, and Ferraz
, A.
, 2014
, “Mechatronic System for ABO Human Blood Typing
,” ASME J. Med. Devices
, 8
(4
), p. 044507
.10.
Bezerra
, K.
, Ferraz
, A.
, Carvalho
, V.
, Machado
, J.
, Matos
, D.
, and Soares
, F. O.
, 2012
, “Advanced Design of a Mechatronic System for Human Blood Typing
,” Rom. Rev. Precis. Mech. Opt. Mechatronics
, 41
, pp. 144
–150
.Copyright © 2016 by ASME
You do not currently have access to this content.