Trabecular bone tissue is a three-dimensional structure that is difficult to duplicate with in vitro cell cultures or animal models. In an attempt to better understand the underlying mechanisms of tissue response to load, a system to load isolated bone preparations was developed. This ex vivo bone culture and loading system, given the name of ZETOS, compressively loads trabecular bone ( diameter, height) to evaluate its morphological and physiological responses while keeping cells viable. Compliance of the system may change with time, thus requiring recalibration. The purpose of this research was to develop and validate a recalibration protocol for the ZETOS system. Ten reference bodies (RBs) were designed and machined out of aluminum 7075-T6, with a structural rigidity range representative of trabecular bone (, or apparent elastic modulus of ). Finite element analysis (FEA) was used to calculate the rigidity of each RB and was validated with physical testing in a universal testing machine. Results from FEA were then used to calibrate the system and relate force, piezoelectric actuator expansion, and specimen compressive deformation through a surface generated by spline interpolation, thus creating a calibration table. Calibration of ZETOS was verified by testing the RBs as well as three custom-made, metal springs and comparing measured rigidity to that calculated by FEA. Mean percent difference of FEA results with respect to those from physical testing was 3.28%. The mean percent difference of RB rigidity found with ZETOS with respect to rigidity found with FEA was 1.12% and for the metal springs, the mean percent difference was 1.74%. The calibration procedure for the ZETOS bone loading system has been successfully applied and verified. The use of RBs and FEA allows users to easily and periodically evaluate and recalibrate the system. Accuracy in studies of human bone mechanotransduction in a controlled environment can therefore be achieved. The recalibration procedure is relevant for other ZETOS users and may serve as the basis for calibration of other testing systems for small specimens of compliant materials.
Skip Nav Destination
e-mail: garcia1@wisc.edu
e-mail: ploeg@engr.wisc.edu
Article navigation
March 2008
Research Papers
A Calibration Procedure for a Bone Loading System
Sylvana García-Rodríguez,
Sylvana García-Rodríguez
Department of Mechanical Engineering,
e-mail: garcia1@wisc.edu
University of Wisconsin—Madison
, 1513 University Avenue, Madison, WI 53706-1572
Search for other works by this author on:
Everett L. Smith,
Everett L. Smith
Department of Population Health Sciences,
University of Wisconsin—Madison
, 1300 University Avenue, Room 1097, Madison, WI 53706
Search for other works by this author on:
Heidi-Lynn Ploeg
Heidi-Lynn Ploeg
Department of Mechanical Engineering,
e-mail: ploeg@engr.wisc.edu
University of Wisconsin—Madison
, 1513 University Avenue, Madison, WI 53706-1572
Search for other works by this author on:
Sylvana García-Rodríguez
Department of Mechanical Engineering,
University of Wisconsin—Madison
, 1513 University Avenue, Madison, WI 53706-1572e-mail: garcia1@wisc.edu
Everett L. Smith
Department of Population Health Sciences,
University of Wisconsin—Madison
, 1300 University Avenue, Room 1097, Madison, WI 53706
Heidi-Lynn Ploeg
Department of Mechanical Engineering,
University of Wisconsin—Madison
, 1513 University Avenue, Madison, WI 53706-1572e-mail: ploeg@engr.wisc.edu
J. Med. Devices. Mar 2008, 2(1): 011006 (6 pages)
Published Online: March 11, 2008
Article history
Received:
June 27, 2007
Revised:
February 5, 2008
Published:
March 11, 2008
Citation
García-Rodríguez, S., Smith, E. L., and Ploeg, H. (March 11, 2008). "A Calibration Procedure for a Bone Loading System." ASME. J. Med. Devices. March 2008; 2(1): 011006. https://doi.org/10.1115/1.2889059
Download citation file:
Get Email Alerts
Cited By
Experimental Investigation of the Calcified Plaque Material Removal Rate in Coronary Rotational Atherectomy
J. Med. Devices (December 2023)
A Novel Design Method for the Knee Joint of the Exoskeleton Based on the Modular Wearable Sensor
J. Med. Devices (December 2023)
Assessment of a Novel Application of the Capture-Trap-Terminate Approach for Treating Aerosol Products During Dental Procedures
J. Med. Devices (December 2023)
Related Articles
Design of a Dynamic Stabilization Spine Implant
J. Med. Devices (June,2009)
Measurements of the Static Friction Coefficient Between Bone and Muscle Tissues
J Biomech Eng (August,2010)
The Biomechanics of Human Femurs in Axial and Torsional Loading: Comparison of Finite Element Analysis, Human Cadaveric Femurs, and Synthetic Femurs
J Biomech Eng (February,2007)
A Biomechanical and Finite Element Analysis of Femoral Neck Notching During Hip Resurfacing
J Biomech Eng (April,2009)
Related Proceedings Papers
Related Chapters
Novel and Efficient Mathematical and Computational Methods for the Analysis and Architecting of Ultralight Cellular Materials and their Macrostructural Responses
Advances in Computers and Information in Engineering Research, Volume 2
Estimating Resilient Modulus Using Neural Network Models
Intelligent Engineering Systems Through Artificial Neural Networks, Volume 17
Application of Non-Linear Elastic Wave Spectroscopy (NEWS) to In Vitro Damage Assessment in Cortical Bone
Biomedical Applications of Vibration and Acoustics in Imaging and Characterizations