Cochlear implants have become a standard treatment for many with severe to profound sensorineural hearing loss. However, delicate cochlear structures can be damaged during surgical insertion, which can lead to loss of residual hearing and decreased implant effectiveness. We propose a magnetic guidance concept in which a magnetically tipped cochlear implant is guided as it is inserted into the cochlea. In a scaled in vitro experimental study, we record insertion forces for nonguided and magnetically guided insertion experiments and compare the results. Results indicate that magnetic guidance reduced insertion forces by approximately 50%. Using first principles, we discuss the effects of scaling down our in vitro experiments, and account for realistic clinical dimensions. We conclude that scale–down effects are negligible, but to produce the same field strength as in our experiments and provide sufficient clearance between the patient and the manipulator, the magnet dimensions should be increased by approximately four times.
Skip Nav Destination
e-mail: james.r.clark@utah.edu
e-mail: l.leon@utah.edu
e-mail: warrenf@ohsu.edu
e-mail: jake.abbott@utah.edu
Article navigation
September 2012
Design Innovation Paper
Magnetic Guidance of Cochlear Implants: Proof-of-Concept and Initial Feasibility Study
James R. Clark,
e-mail: james.r.clark@utah.edu
James R. Clark
Department of Mechanical Engineering, University of Utah
, Salt Lake City, UT
84112
Search for other works by this author on:
Lisandro Leon,
e-mail: l.leon@utah.edu
Lisandro Leon
Department of Mechanical Engineering, University of Utah
, Salt Lake City, UT
84112
Search for other works by this author on:
Frank M. Warren,
e-mail: warrenf@ohsu.edu
Frank M. Warren
Department of Otolaryngology, Division of Otology and Skull Base Surgery, Oregon Health & Science University
, Portland, OR
97239
Search for other works by this author on:
Jake J. Abbott
e-mail: jake.abbott@utah.edu
Jake J. Abbott
Department of Mechanical Engineering, University of Utah
, Salt Lake City, UT
84112
Search for other works by this author on:
James R. Clark
Department of Mechanical Engineering, University of Utah
, Salt Lake City, UT
84112 e-mail: james.r.clark@utah.edu
Lisandro Leon
Department of Mechanical Engineering, University of Utah
, Salt Lake City, UT
84112 e-mail: l.leon@utah.edu
Frank M. Warren
Department of Otolaryngology, Division of Otology and Skull Base Surgery, Oregon Health & Science University
, Portland, OR
97239e-mail: warrenf@ohsu.edu
Jake J. Abbott
Department of Mechanical Engineering, University of Utah
, Salt Lake City, UT
84112e-mail: jake.abbott@utah.edu
J. Med. Devices. Sep 2012, 6(3): 035002 (8 pages)
Published Online: August 10, 2012
Article history
Received:
July 29, 2011
Revised:
April 3, 2012
Online:
August 10, 2012
Published:
August 10, 2012
Citation
Clark, J. R., Leon, L., Warren, F. M., and Abbott, J. J. (August 10, 2012). "Magnetic Guidance of Cochlear Implants: Proof-of-Concept and Initial Feasibility Study." ASME. J. Med. Devices. September 2012; 6(3): 035002. https://doi.org/10.1115/1.4007099
Download citation file:
Get Email Alerts
A Portable Aspiration-Assisted Device for End-Cut Prostate Biopsy of Large Tissue Sample
J. Med. Devices (June 2025)
Paper errata statement
J. Med. Devices
Related Articles
A Scalable Model for Human Scala-Tympani Phantoms
J. Med. Devices (March,2011)
Robotic Visible Forceps Manipulator With a Novel Linkage Bending Mechanism
J. Mechanisms Robotics (February,2019)
Vaginal Approach for Uterus Separation During Laparoscopic Hysterectomy
J. Med. Devices (June,2010)
A Manual Insertion Mechanism for Percutaneous Cochlear Implantation
J. Med. Devices (June,2010)
Related Proceedings Papers
Related Chapters
Structure of Magnetic Actuator
Magnetic Bearings for Mechanical Cardiac Assist Devices
Feedback-Aided Minimum Joint Motion
Robot Manipulator Redundancy Resolution
QP Based Encoder Feedback Control
Robot Manipulator Redundancy Resolution