Visual, vibrotactile, and auditory cues have proven successful in numerous applications to supplement or in some cases completely replace missing sensory information. Sensory substitution using vibrotactile stimulation has been effective in improving postural stability during stationary tasks and tasks involving perturbed stance. The challenge increases, however, when designing a wearable device that provides meaningful information during a dynamic task such as walking. Techniques that directly apply the feedback strategies effective in stance (trunk tilt) to walking have largely proven ineffective (excluding heel-to-toe walking, which is essentially a series of standing balance tasks). We have demonstrated a device for correcting vestibulopathic gait using a novel feedback methodology that was co-developed with physical therapists specializing in balance rehabilitation. The device supplies vibrotactile cues based on factors during walking that are considered important by physical therapists, including gait velocity, stride length, and gaze. The device consists of three independent units, each consisting of an inertial measurement unit (IMU), vibrotactile display, and microprocessor. Head tilt (which approximates eye gaze), trunk tilt, stride length, and velocity are estimated by the IMUs and displayed to the patient in the form of vibrotactile cues on the head, trunk, and tibia, respectively. Algorithms were developed to estimate stride length and gait velocity in real time from measured heel-strike and toe-off events. Feedback of the head pitch angle is provided continuously to the subject, while gait velocity and stride length feedback are provided during heel strike events only. Preliminary results demonstrate that healthy subjects can interpret this feedback to correct their head pitch and adjust their stride length and gait velocity.
Skip Nav Destination
Article navigation
Design Of Medical Devices Conference Abstracts
Vibrotactile Balance Rehabilitation Gait Assist Device
V. V. Vichare,
V. V. Vichare
University of Michigan
, Ann Arbor, USA
Search for other works by this author on:
B. C. Lee,
B. C. Lee
University of Michigan
, Ann Arbor, USA
Search for other works by this author on:
W. Carender,
W. Carender
University of Michigan
, Ann Arbor, USA
Search for other works by this author on:
K. H. Sienko
K. H. Sienko
University of Michigan
, Ann Arbor, USA
Search for other works by this author on:
V. V. Vichare
University of Michigan
, Ann Arbor, USA
B. C. Lee
University of Michigan
, Ann Arbor, USA
W. Carender
University of Michigan
, Ann Arbor, USA
K. H. Sienko
University of Michigan
, Ann Arbor, USAJ. Med. Devices. Jun 2009, 3(2): 027509 (1 pages)
Published Online: June 30, 2009
Article history
Published:
June 30, 2009
Citation
Vichare, V. V., Lee, B. C., Carender, W., and Sienko, K. H. (June 30, 2009). "Vibrotactile Balance Rehabilitation Gait Assist Device." ASME. J. Med. Devices. June 2009; 3(2): 027509. https://doi.org/10.1115/1.3135150
Download citation file:
596
Views
Get Email Alerts
Cited By
A Better Way to Visualize the Cervix: A Low-Cost Cervical Cancer Screening Device for LMIC Settings
J. Med. Devices (April 2025)
Comparative Survey-Based Study of Noninvasive Saliva Collection Devices
J. Med. Devices (April 2025)
Related Articles
The Design of a Cell-Phone Based Balance-Training Device
J. Med. Devices (June,2009)
Medtech Design in Interdisciplinary Clinical Innovation Teams
J. Med. Devices (June,2009)
An Advanced Patient Lift and Transfer Device for the Home
J. Med. Devices (March,2010)
Related Proceedings Papers
Related Chapters
Stability and Range
Design and Analysis of Centrifugal Compressors
Diagnostics of Complex and Rare Abnormalities Using Ensemble Decomposition Learning
International Conference on Computer and Computer Intelligence (ICCCI 2011)
Introduction
Mechanical Blood Trauma in Circulatory-Assist Devices